<?xml version="1.0" encoding="UTF-8"?>
<article xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:ali="http://www.niso.org/schemas/ali/1.0/" article-type="research-article" dtd-version="1.2" xml:lang="en">
  <front>
    <journal-meta>
      <journal-id journal-id-type="issn">1561-5405</journal-id>
	    <journal-id journal-id-type="doi">10.24151/1561-5405</journal-id>	  
      <journal-id journal-id-type="publisher-id">Proceedings of Universities. Electronics</journal-id>
      <journal-title-group>
        <journal-title xml:lang="en">Scientifical and technical journal "Proceedings of Universities. Electronics"</journal-title>
        <trans-title-group xml:lang="ru">
          <trans-title>Научно-технический журнал «Известия высших учебных заведений. Электроника»</trans-title>
        </trans-title-group>        
      </journal-title-group>      
      <issn publication-format="print">1561-5405</issn>
      <issn publication-format="online">2587-9960</issn>
      <publisher>
        <publisher-name xml:lang="en">National Research University of Electronic Technology</publisher-name>
        <publisher-name xml:lang="ru">Национальный исследовательский университет "Московский институт электронной техники"</publisher-name>
      </publisher>
    </journal-meta>
    <article-meta>                                    
      
    <article-id pub-id-type="doi">10.24151/1561-5405-2018-23-2-133-140</article-id><article-id pub-id-type="udk">621.1.016.7:628.8</article-id><article-categories><subj-group><subject>Технологические процессы и маршруты</subject></subj-group></article-categories><title-group><article-title xml:lang="en">Evaluation of Efficiency of Air Conditioning System of Clean Rooms with Regard to Thermodynamic Parameters</article-title><trans-title-group xml:lang="ru"><trans-title>Оценка эффективности системы кондиционирования воздуха чистых производственных помещений с учетом термодинамических параметров</trans-title></trans-title-group></title-group><contrib-group><contrib contrib-type="author"><string-name xml:lang="ru">Гаврилин Вячеслав Андреевич </string-name><name-alternatives><name xml:lang="ru"><surname>Гаврилин</surname><given-names>Вячеслав Андреевич </given-names></name><name xml:lang="en"><surname>Andreevich</surname><given-names>Gavrilin Vyacheslav</given-names></name></name-alternatives><string-name xml:lang="en">Gavrilin Vyacheslav Andreevich</string-name><xref ref-type="aff" rid="AFF-1"/></contrib><contrib contrib-type="author"><string-name xml:lang="ru">Каракеян Валерий Иванович</string-name><name-alternatives><name xml:lang="ru"><surname>Каракеян</surname><given-names>Валерий Иванович</given-names></name><name xml:lang="en"><surname>Karakeyan</surname><given-names>Valery I.</given-names></name></name-alternatives><string-name xml:lang="en">Valery I. Karakeyan</string-name><xref ref-type="aff" rid="AFF-2"/></contrib><contrib contrib-type="author"><string-name xml:lang="ru">Рябышенков Андрей Сергеевич</string-name><name-alternatives><name xml:lang="ru"><surname>Рябышенков</surname><given-names>Андрей Сергеевич</given-names></name><name xml:lang="en"><surname>Riabyshenkov</surname><given-names>Andrey S.</given-names></name></name-alternatives><string-name xml:lang="en">Andrey S. Riabyshenkov</string-name><xref ref-type="aff" rid="AFF-2"/></contrib><aff id="AFF-1" xml:lang="ru">Национальный исследовательский университет «МИЭТ»</aff><aff id="AFF-2" xml:lang="ru">Национальный исследовательский университет «МИЭТ», г. Москва, Россия</aff></contrib-group><fpage>133</fpage><lpage>140</lpage><self-uri>http://ivuz-e.ru/issues/2-_2018/otsenka_effektivnosti_sistemy_konditsionirovaniya_vozdukha_chistykh_proizvodstvennykh_pomeshcheniy_s/</self-uri><self-uri content-type="pdf">http://ivuz-e.ru/download/2_2018_2159.pdf</self-uri><abstract xml:lang="en"><p>The energy intensity of the air conditioning system of clean rooms of microelectronics is an important indicator of the competitiveness in the branch. The proposed approach makes it possible to adequately assess the thermodynamic perfection of the system on the basis of various schemes for the formation of aerodynamic regime by compiling the exergic balance flows of the substance and determining the exergy losses in it. This serves as an objective prerequisite for optimizing the hardware-technology solution by the energy intensity criterion, because the thermodynamic indices of the system quality are the necessary but not sufficient condition for making a final scheme decision. It has been proposed to use as an index for evaluating the economical level of the air conditioning system the exergy cost content. The thermo-economic criterion for selecting a technological scheme is the minimum objective function to minimize the cost of a unit of specific air exergy. Based on the exergic analysis and by the constructing diagrams of the exergy and cost parameters of the system, the conditions for the most effective provision of a technological microclimate of clean rooms are determined on external conditions. The calculation has shown that the thermodynamic and economic optimums in the analyzed systems mainly coincide. Thus, the thermodynamic approach reveals the non-effective elements of SLE by the level of specific exergy, and the thermodynamic analysis makes it possible to determine the feasibility of using additional hardware and technology components of the system under study.</p></abstract><trans-abstract xml:lang="ru"><p>Энергоемкость системы кондиционирования воздуха чистых производственных помещений - важный показатель конкурентоспособности микроэлектронной отрасли. Предлагаемый подход позволяет на основе различных схем формирования аэродинамического режима адекватно оценить термодинамическое совершенство системы путем составления эксергетических балансов потока вещества и определения потерь в ней эксергии. Это служит объективной предпосылкой оптимизации аппаратно-технологического решения по критерию энергоемкости. Сопоставление удельных эксергетических потоков в элементах системы позволяет установить участки, подлежащие улучшению. Предложено в качестве показателя оценки экономического уровня системы кондиционирования воздуха чистых производственных помещений использовать стоимостное содержание эксергии, поскольку термодинамические показатели качества системы - необходимое, но недостаточное условие для принятия окончательного схемного решения. Термоэкономическим критерием для выбора технологической схемы служит минимум целевой функции минимизации стоимости единицы удельной эксергии воздуха. На основе эксергетического анализа и посредством построения диаграмм эксергетических и стоимостных показателей системы определен критерий наиболее эффективного обеспечения технологического микроклимата чистых производственных помещений в зависимости от внешних условий. Расчетным путем показано, что термодинамический и термоэкономический оптимумы в анализируемых системах в основном совпадают. Таким образом, термодинамический подход выявляет неэффективные элементы системы кондиционирования воздуха по уровню удельной эксергии, а термоэкономический анализ позволяет определить целесообразность использования дополнительных аппаратно-технологических компонентов исследуемой системы.</p></trans-abstract><kwd-group xml:lang="ru"><kwd>система кондиционирования воздуха</kwd><kwd>эксергетический баланс</kwd><kwd>эффективность</kwd><kwd>показатели эксергии</kwd></kwd-group><funding-group/></article-meta>
  </front>
  <body/>
  <back>
    <ref-list><ref id="B1"><label>1.</label><mixed-citation xml:lang="ru">Каракеян В.И., Дисветова Н.М. Система кондиционирования воздуха чистых помеще-ний как объект термодинамического анализа // Актуальные проблемы повышения эффек-тивности производств микроэлектроники: Сб. науч. тр. МИЭТ / под ред. В.И. Каракеяна. – М.: МИЭТ, 2016. – С. 3–10.</mixed-citation></ref><ref id="B2"><label>2.</label><mixed-citation xml:lang="ru">Цыганков А.В., Гримитлин А.М. Состояние и перспективы развития систем конди-ционирования воздуха // Вестник Международной академии холода. – 2013. – № 4. – С. 47–50.</mixed-citation></ref><ref id="B3"><label>3.</label><mixed-citation xml:lang="ru">Рябышенков А.С. Термодинамический анализ процесса воздухоподготовки чистых по-мещений // Изв. вузов. Электроника. – 2017. – Т. 22. – №4. – С. 341–349.</mixed-citation></ref><ref id="B4"><label>4.</label><mixed-citation xml:lang="ru">Бродянский В.М., Фратшер В., Михалек К. Эксергетический метод и его приложения / под ред. В.М. Бродянского. – М.: Энергоатомиздат, 1988. – 288 с.</mixed-citation></ref><ref id="B5"><label>5.</label><mixed-citation xml:lang="ru">Шишов В.В. Энтропийно-статистический анализ холодильных циклов для систем кон-диционирования // Инженерный журнал: наука и инновации. – 2012. – № 5 (5). – С. 143–156.</mixed-citation></ref><ref id="B6"><label>6.</label><mixed-citation xml:lang="ru">Рябышенков А.С., Захаров А.Н., Гаврилин В.А. Эксергетический анализ рециркуляци-онной системы кондиционирования и фильтрации воздуха в чистых помещениях // Акту-альные проблемы повышения эффективности производств микроэлектроники: Сб. науч. тр. МИЭТ / под ред. В.И. Каракеяна. – М.: МИЭТ, 2016. – С. 28–33.</mixed-citation></ref><ref id="B7"><label>7.</label><mixed-citation xml:lang="ru">Архаров А.М., Шишов В.В. Энтропийно-статистический анализ распределения затрат энергии на компенсацию необратимости рабочих процессов систем кондиционирования // Вестник МГТУ им. Н.Э. Баумана. Сер. Машиностроение. – 2013. – №2. – С. 84–93.</mixed-citation></ref></ref-list>    
  </back>
</article>
